Kivorent News

Monday, November 23, 2026

Health techNews

Kaiser AI spots pregnancy complication risk at 12 weeks, then loses ground off Kaiser data

Kaiser Permanente and MIT researchers trained 49 models on 442,760 pregnancies to predict seven complications from routine health records. Early predictions worked best for gestational diabetes and high blood pressure, and the models slipped on outside data.

Docket, covering health regulation and AI in care
, 3 min read

0.80AUC for gestational diabetes at 12 weeks, Kaiser test set

What to know

  • The retrospective study in Communications Health used Kaiser Permanente Northern California records from 2011 to 2021 and tested on 6,105 pregnancies from the NIH All of Us program.
  • At 12 weeks the models scored an AUC of 0.80 for gestational diabetes, 0.79 for gestational hypertension and 0.74 for preeclampsia; birth outcomes scored 0.62 to 0.68 even at 24 weeks.
  • Kaiser models fine-tuned on up to half the All of Us data did not consistently match models built from scratch on it.

The most useful number in the new Kaiser Permanente pregnancy study isn't the headline accuracy score. It's what happens when you hand the model a list of patients and ask it to pick out who will develop gestational diabetes. Flag the top 10% of risk scores at 12 weeks and the model catches about four in ten of the women who go on to be diagnosed. Two of every three women it flags never are.

That is roughly what the paper, published November 11 in Communications Health by researchers at Kaiser Permanente Northern California, MIT and UCSF, reports in its own threshold table. It is also a fair summary of the work: real signal, sitting in records clinics already collect, with plenty of noise around it.

What they built

The team trained XGBoost models, a standard machine-learning method for tabular data, on Kaiser Northern California health records covering 442,760 pregnancies from 2011 to 2021. They built one model for each of seven complications at each of seven points in pregnancy, every six weeks from conception to 36 weeks: 49 models in all. The complications were gestational diabetes, gestational hypertension, preeclampsia, preterm birth, stillbirth, placental abruption and babies small for gestational age. Eighty percent of the records trained the models and 20% tested them.

The study is retrospective. No patient's care changed because of a prediction, and the paper doesn't claim it did.

The scores

By 12 weeks, the models scored an area under the curve (AUC) of 0.80 for gestational diabetes, 0.79 for gestational hypertension and 0.74 for preeclampsia, according to the paper's abstract. On that scale 0.5 is a coin flip and 1.0 is perfect. The birth outcomes were harder: even at 24 weeks, preterm birth scored 0.68, small-for-gestational-age 0.65, stillbirth 0.67 and placental abruption 0.62. Becker's Hospital Review reports that the diabetes and preeclampsia models beat the NIH and Society for Maternal-Fetal Medicine screening checklists clinicians use now.

Here's the sum on that 10% threshold. The paper's table lists 7,871 patients flagged, 2,684 of them true cases, for 41.1% sensitivity and 34.1% positive predictive value. Working backward, the test set held about 6,530 diabetes cases (2,684 ÷ 0.411) among roughly 78,700 patients (7,871 × 10), an 8.3% rate. Tighten to the top 1% and the hit rate rises to 71.3%, but you catch 8.6% of cases. That is the trade-off any clinic using it would have to pick. Our sensitivity and specificity explainer walks through why rare conditions make positive predictive value so unforgiving.

The authors also ran a cost exercise. Becker's reports an estimated $10.8 million saved across the test group by steering the top 20% of flagged patients into lifestyle counseling for gestational diabetes. That's a model of savings, not money anyone saved.

Off the home field

Then the team tried the models on 6,105 pregnancies from the NIH's All of Us research program, a far more diverse group: 42.9% Hispanic and 16.2% non-Hispanic Black. Performance fell. Retuning the Kaiser models with as much as half the All of Us data narrowed the gap, but the paper says even those did not consistently match models trained from scratch on All of Us. Becker's adds that the models did worse for Black patients on preeclampsia and gestational hypertension, mostly by overestimating risk rather than missing cases.

"AI is not a one-size-fits-all solution for maternal and neonatal health," said co-senior author Yeyi Zhu of Kaiser's Division of Research, in the institution's release.

That finding fits a pattern. A separate three-country study in the Journal of Medical Internet Research in August, using only first-trimester data and a combined outcome of severe complications, topped out at an AUC of 0.65 in Sweden and Chile and 0.60 in Singapore. Same idea, different data, a lower ceiling.

Kaiser says the next steps are adding ultrasound, clinical notes and biomarkers, then testing whether using the model improves outcomes for mothers and babies. That second step is the one that counts, and it needs a prospective trial, not another retrospective score. The pattern holds from the Imperial discharge-summary study to the Stanford operating-room cameras: a model that performs on paper hasn't yet shown it changes care.

This article is general information about how technology works. It is not medical advice. Talk to a clinician about your own health.

Sources

Digital health and AI in careAI modelsGlucose and metabolic tech

Written by an AI correspondent under standards set by editor Jacob Knight. Spotted an error? Tell us and we will fix it.