Kivorent News

Wednesday, November 25, 2026

Health techExplainer

What FDA-cleared AI triage software for radiology actually does, explained

Many FDA-cleared radiology AI tools are computer-aided triage (CADt) devices: software that flags a suspected urgent finding and moves the scan up a radiologist's list. Here is what that clearance covers, what it leaves out, and how to read the numbers.

Docket, covering health regulation and AI in care
, 3 min read

2018Year the FDA created the radiology triage device category

What to know

  • Computer-aided triage (CADt) software flags scans with a suspected urgent finding so a radiologist can open them sooner; it does not make a diagnosis.
  • The category, 21 CFR 892.2080, was created through a De Novo grant in 2018, and most triage tools since have been cleared through the 510(k) pathway.
  • A scan the software does not flag is not cleared: it stays in the normal queue and the radiologist still reads every study in full.

Every radiologist starts a shift with a list, and the order of that list is the whole product. Computer-aided triage software, the most common kind of AI the FDA clears for imaging, does one narrow thing: it looks at a scan as it arrives, decides whether it might show something urgent such as a large-vessel stroke or a collapsed lung, and if so pushes that study toward the top or sends an alert. Then it gets out of the way.

That modesty is written into the rules, and it's worth knowing before reading the next press release that calls a triage tool a diagnostic breakthrough.

A category built on not diagnosing

The FDA created the category in February 2018, when it granted a De Novo request for Viz.ai's ContaCT, software that looked for suspected large-vessel blockages on CT angiography of the head and alerted a stroke specialist through a phone app. The De Novo set up a new regulation, 21 CFR 892.2080, "radiological computer aided triage and notification software," as a Class II device with special controls. Once that slot existed, later tools could reach market through the cheaper 510(k) route by pointing to an earlier one as a predicate. Most triage tools since, from intracranial bleed flags to the nine-finding abdominal CT product a2z Radiology AI got cleared in November 2026, have taken that path.

The intended-use language in these clearances follows a pattern. The software is for worklist prioritization or notification. It is not meant to mark the image for diagnosis. Any preview image it sends to a phone is for information only. And the clinician reviews the full study under the normal standard of care regardless of what the software said.

That is a real difference from computer-aided detection, which puts marks on the image to point a reader at a spot, and computer-aided diagnosis, which characterizes what it found. Those claims sit in other regulations and generally need more evidence.

The half nobody advertises: negatives

A triage tool's "no" means nothing official. A scan it doesn't flag isn't declared normal; it just waits its turn. That is why the FDA can tolerate a tool that misses some cases, and why a vendor's sensitivity figure should never be read as "the share of strokes that will be caught." The radiologist was always going to read the scan. The software's job is to make some reads happen earlier.

It also means the cost of errors lands in two places. A miss costs time, since the urgent scan sits in line as it would have without AI. A false alarm costs attention: someone opens a study early for nothing, and enough of those teach people to ignore the alert.

Reading the numbers in a clearance

A 510(k) summary for a triage device usually reports sensitivity and specificity on a retrospective test set, often with a few hundred cases, and frequently a time-to-notification figure showing how many minutes sooner the device alerted than the standard workflow would have opened the scan.

Three caveats apply every time. Test sets are often enriched with positive cases, so the share of alerts that turn out to be real in daily use, the positive predictive value, will usually be lower than the submission implies, sometimes much lower when the finding is rare. Performance can drift on different scanners, protocols and patient groups than the ones tested. And time-to-notification measures when the alert fired, not when anyone read the scan, called the patient or changed treatment.

What a triage clearance doesn't show is that patients do better. That question needs outcome studies in real hospitals, and the clearance doesn't require them.

Updates and versions

Triage models get retrained. Whether a new version needs a fresh submission depends on what changed and whether the maker has an FDA-authorized predetermined change control plan; our explainer on when a software update needs a new 510(k) covers the line. For a reader, the practical upshot is simple: the version in a hospital today may not be the one whose numbers are in the public summary, and the summary won't tell you.